Showing posts with label What is design of base plate?. Show all posts
Showing posts with label What is design of base plate?. Show all posts

Monday, April 13, 2020

What is design of base plate?, What is required size of Base plate for Steel Structure?


Design of Base Plate :

Grade of steel used                                             fy  =  250 MPa
Grade of concrete used,       
For  M25                              fck =  25 MPa Bearing strength of concrete,=0.45 x fck                               
As per Cl.34.4 of IS :456:20000
=0.45  x  25   =  11.25 N/mm2
Max. bearing pressure should not exceed the bearing strength equal to 0.6 x fc as per Cl.7.4.1 of IS 800 :2007
0.6  x  25  = 15 N/mm2
partial safety factor                                     γm0   = 1.1
Sectional Properties of column  2 NB TUBE 150  x  4.85 THIK. 
b     =  168 mm    
A  =   24.90 cm2
d    = 150 mm
Maximum support reaction at each leg  =   316 KN
(Ref : " Design of Trestles" in design notes )     =  316000 N
Required area of slab Base           
=  316000  X /          11.25  
=28088.89 mm^2
provide size of base plate more than                              = 28088.9 mm^2                                      =167.5974012 mm^2
proposed section for Base plate    280  x  280  mm
Thickness of plate provided = 22 mm
Length of the base plate = 280 mm
Width of the base plate  =280 mm
Area of base plate            
Abp =  280  x   280    
                                        
  = 78400 mm^2

        Hence SafeDesign Ok        

Yield strength of the steel                                                  =   250 N/mm2
Stress on base plate                                                               w = 4.031 N/mm2
Check for Base plate thickness
Depth of column section                                                            = 168 mm
Total width column section                                                         =150 mm
Smaller projection  b = ( 280  -  150)  /  2     =65 mm 
Larger  projection  a  = (280 - 168)/   2    = 55.85 mm
Thickness of the base plate required,  T  =   2.5 x  4.03 x (65  x  65
-  0.3  x ( 5.85 x 55.85 ) x  1.1/250 
T    =   12.0762 m
Provided thickness of base  plate                                             =    22 mm
        HENCE  SAFE      


Types of drawings in any construction project:

Types of drawings in any construction project: 1. IFC Drawing: Detailed drawings considered final, issued, and approved by the design team f...