Tuesday, September 15, 2020

What is Composition of Brick Earth?

Composition of Brick Earth 
the main constituents of Earth for brick making are
 Silica or Sand
 A good brick earth contains about 50% to 60% of silica. 
Alumina or Clay 
A good brick earth contains about 20% to 30% of alumina.  
Lime 
A good brick earth contains up to 5% of lime. 
Magnesia 
A good brick earth contains up to 3% of magnesia. It is used for decreasing the shrinkage of bricks.
 Oxide of Iron 
A good brick earth contains up to 6% of iron oxide. It helps lime to fuse is silica and gives red colour to the bricks.
 it may be noted that 
(a) The excess of alumina in the clay (brick earth) makes the brick crack and warp during drying process. 
(b) The excess of silica in the clay makes the brick brittle and weak after burning. 
(c) The excess of lime in the clay causes the bricks to melt and distort during burning. 
(d) The alkaline salt present in the bricks, absorb moisture from air which on drying leaves powder deposit on the brick
 (e) This effect is known as efflorescence. It is also caused if the clay used for making bricks contain pyrite and the water used for pugging the clay contain gypsum. 

Manufacturing of Bricks  
 Preparation of Clay 
(I) After removal of vegetation, the clay deposit is excavated in steps rather than in layers to ensure a better distribution of the several constituents which vary in different proportions at different depths.Further processing of the clay depends on the type of bricks to be made.
 (ii)  For ordinary country bricks, very little preparation. except mixing by treading is resorted to. 
(iii)  For making first class facing bricks, the clay is allowed to weather by keeping it exposed to open air for a considerable period, so that the lumps of clay break down into smaller particles and get matured.
 (iv)  As a further refinement for making very superior bricks, the clay is washed and processed before moulding into bricks.
(v)  For making clay tiles also we use the clay that has been processed.

what is Bricks & What is Classification of Bricks.

Bricks
Bricks are block of tempered clay by plastic moulded to suitable shapes.
they are dried in Sun and then burnt therefore as to make them strong hard and durable.
the standard size of  bricks are 19 cm x 9 cm x 4 cm or 19 cm x 9 cm x 9 cm.
the specific gravity of bricks is about 2.

the no. of bricks contain for one cubic metre of brick masonry are 550.

Classification of Bricks
1.) First-Class  Brick
in this bricks are well burnt having smooth and even surface with perfect rectangular shape and uniform reddish colour.
these bricks should not absorb water more than 20% of its own dry weight after 24 hours immersion in water.
it should have a minimum crushing strength of 10.5 MN/m^2.
2.) Second Class Bricks ЁЯз▒
the second Class Bricks are slightly over burnt having rough surface and not perfectly rectangular in shape.
these bricks should not absorb water more than 22% of its own dry weight after 24 hours immersion in water.
3.) Third Class Bricks
Third Class Bricks are not properly burnt (under burnt) in the kiln and hence these are soft and can be easily broken. 
these bricks should not absorb water more than 25% of its own dry weight after 24 hours immersion in water.
4.) Jhama Bricks
Jhama bricks are over burnt with irregular shape.
these bricks are dark bluish in colour.

Wednesday, September 9, 2020

Saturday, August 22, 2020

Important points of Civil Engineer

1.)  POINT OF CONTRAFLEXURE: 
The point of Contraflexure is a point whese Bending Moment changes its sign (BM is zero). 
 2.) GRADE OF CONCRETE & MIX PROPORTION: 
               C:S:A 
1.) M-75 1:4:8 
2.) M-10 1:3:6 
3.) M-15 1:2:4 
4.) M-20 1:1-5 :3 
5.) M-25 1:1:2 3. 
Notes:- C:S:A┬░ C-- Cement, S---Sand, 
A--- Aggregate
3) MINIMUM CLEAR COVER: 
As per IS Code 456:2000
a} Footing = 40mm
b} Column = 50 mm 
c} Slab & stairs = 15 mm 
d} Beam  = 25 mm 
4.) DENSITY 
i} R.C.C = 2500 kg/m┬│
ii} Steel - 7850 kg/m┬│ 
iii} Brick = 1600 - 1920 kg/m┬│ 
iv} PCC= 2400 kg/m┬│ 
v} Cement = 1440 kg/m┬│

Saturday, August 8, 2020

рдПрдХ рдкрд╛рд▓рдЯреЗрдХреНрдирд┐рдХ рдореЗрдВ рдЫрд╛рддреНрд░рд╛рд╡рд╛рд╕ рддрдерд╛ рд╕реНрдЯрд╛рдл рдХреЙрд▓реЛрдиреА рдХреЗ рдирд┐рд╡рд╛рд╕рд┐рдпреЛрдВ рдХреА рдХреБрд▓ рд╕рдВрдЦреНрдпрд╛ 1000 рд╡реНрдпрдХреНрддрд┐ рд╣реИред рддрдерд╛ рдкреНрд░рддрд┐ рд╡реНрдпрдХреНрддрд┐ 135 рд▓реАрдЯрд░ рдкрд╛рдиреА рдЙрдкрд▓рдмреНрдз рдХрд░рд╛рдпрд╛ рдЧрдпрд╛ рд╣реИред рдЬрд┐рд╕рдХрд╛ 80% рднрд╛рдЧ рдЕрдкрд╢рд┐рд╖реНрдЯ рдЬрд▓ (Waste water) рдХреЗ рд░реВрдк рдореЗрдВ рдмрд╛рд╣рд░ рдЖрддрд╛ рд╣реИред рд╕рдВрд╕реНрдерд╛ рдХреЗ рд▓рд┐рдП I.S. 1742 рдореЗрдВ рджреА рдЧрдИ рддрд╛рд▓рд┐рдХрд╛ рдХреА рд╕рд╣рд╛рдпрддрд╛ рд╕реЗ рдЙрдЪрд┐рдд рд╡реНрдпрд╛рд╕ рдХреА рд╕реАрд╡рд░ рдХрд╛ рдЕрднрд┐рдХрд▓реНрдкрди рдХрд░реЗрдВ?

рдкрд╛рд▓рд┐рдЯреЗрдХреНрдирд┐рдХ рдЫрд╛рддреНрд░рд╛рд╡рд╛рд╕ рдФрд░ рд╕реНрдЯрд╛рдл рдХрд╛рд▓реЛрдиреА рдореЗрдВ рдХреБрд▓ рдЬрд▓ рд╕рдкреНрд▓рд╛рдИ=1000├Ч135
                       =1,35,000 рд▓реАрдЯрд░ рдкреНрд░рддрд┐рджрд┐рди
рдЪрд┐рддреНрд░:- Sewer Line 
рдЬрд┐рд╕рдХрд╛ 80%рдЕрдкрд╢рд┐рд╖реНрдЯ рдЬрд▓ (Waste water) рдХреЗ рд░реВрдк рдореЗрдВ рдмрд╛рд╣рд░ рд╕реАрд╡рд░ рд▓рд╛рдИрди рдореЗрдВ рдЖ рд░рд╣рд╛ рд╣реИред
(рдкреНрд░рд╢реНрди рдЕрдиреБрд╕рд╛рд░)
           =1,35,000 ├Ч (80/100) рд▓реАрдЯрд░ рдкреНрд░рддрд┐рджрд┐рди
            =108000 рд▓реАрдЯрд░ рдкреНрд░рддрд┐рджрд┐рди
     108000/(24├Ч60├Ч60)
                =1.25 рд▓реАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб
рд╕реАрд╡реЗрдЬ рдХреЗ рдЙрддрд╛рд░ рдЪрдврд╝рд╛рд╡ рдХреЛ рджреЗрдЦрддреЗ рд╣реБрдП рд╕реАрд╡рд░ рдХреА рдХреНрд╖рдорддрд╛ 3 рдЧреБрдирд╛ рдЕрдзрд┐рдХ рд░рдЦреА рдЬрд╛рддреА рд╣реИред
рд╕реАрд╡рд░ рдХреА рдХреНрд╖рдорддрд╛=1.250 ├Ч 3
                      =3.750 рд▓реАрдЯрд░/рд╕реЗрдХреЗрдВрдб
                      =0.003750 рдШрди рдореАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб
рдЪреВрдВрдХрд┐ рд╕реАрд╡рд░ рдХрд╛ 2/3 рднрд╛рдЧ рд╕реЗ рдЕрдзрд┐рдХ рднрд░рд╛ рд╣реБрдЖ рдирд╣реАрдВ рдкреНрд░рд╡рд╛рд╣рд┐рдд рд╣реЛрдиреА рдЪрд╛рд╣рд┐рдПред
рдЕрддрдГ рд╕реАрд╡рд░ рдХреА рдХреБрд▓ рдХреНрд╖рдорддрд╛
                =0.00375 ├Ч1.5
                 =0.005625 рдШрди рдореАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб
                   =0.005625 ├Ч 60
                  =0.3375 рдШрди рдореАрдЯрд░ рдкреНрд░рддрд┐ рдорд┐рдирдЯ
 
               Table.13.4-I.S.1742

 рдЕрддрдГ table 13.4( I.S.1742) рдХреЗ рдЕрдиреБрд╕рд╛рд░ 150 рдорд┐рдореА рд╡реНрдпрд╛рд╕ рдХреА рд╕реАрд╡рд░ рдкрд╛рдИрдк (Sewer Pipe) рдЙрдкрдпреБрдХреНрдд рд░рд╣реЗрдЧрд╛, рдЬрд┐рд╕рдореЗрдВ 0.75 рдореАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб рдХреЗ рд╡реЗрдЧ рдкрд░ Sewage рдкреНрд░рд╡рд╛рд╣рд┐рдд рд╣реЛ рд╕рдХреЗрдЧрд╛ред
рд╕реАрд╡рд░ рдХрд╛ рдврд╛рд▓ 1 IN 100 рджрд┐рдпрд╛ рдЬрд╛рдПрдЧрд╛ред

рдПрдХ рдХреЙрд▓реЛрдиреА рдХреА рдХреБрд▓ рдЬрдирд╕рдВрдЦреНрдпрд╛ 2000 рд╣реИред рддрдерд╛ рдкреНрд░рддрд┐ рд╡реНрдпрдХреНрддрд┐ рдкреНрд░рддрд┐рджрд┐рди 135 рд▓реАрдЯрд░ рдкрд╛рдиреА рд╕рдкреНрд▓рд╛рдИ рдХрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред рдХрд╛рд▓реЛрдиреА рдХреЗ рд▓рд┐рдП рдЙрдЪрд┐рдд рд╡реНрдпрд╛рд╕ рдХреА рд╕реАрд╡рд░ рд▓рд╛рдЗрди рдХрд╛ рдЕрднрд┐рдХрд▓реНрдкрди I.S. 1742 рдХреЗ рдЖрдзрд╛рд░ рдкрд░ рдирд┐рд░реНрдзрд╛рд░рд┐рдд рдХрд┐рдЬрд┐рдПред

рдХреБрд▓ рдЬрд▓ рд╕рдкреНрд▓рд╛рдИ=2000├Ч135
                       =2,70,000 рд▓реАрдЯрд░ рдкреНрд░рддрд┐рджрд┐рди
2,70,000/(24├Ч60├Ч60)=3.124 рд▓реАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб
рд╕реАрд╡реЗрдЬ рдХреЗ рдЙрддрд╛рд░ рдЪрдврд╝рд╛рд╡ рдХреЛ рджреЗрдЦрддреЗ рд╣реБрдП рд╕реАрд╡рд░ рдХреА рдХреНрд╖рдорддрд╛ 3 рдЧреБрдирд╛ рдЕрдзрд┐рдХ рд░рдЦреА рдЬрд╛рддреА рд╣реИред
рд╕реАрд╡рд░ рдХреА рдХреНрд╖рдорддрд╛=3.9124 ├Ч 3
                       =9.372 рд▓реАрдЯрд░/рд╕реЗрдХреЗрдВрдб
                        =0.00938 рдШрди рдореАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб
рдЪреВрдВрдХрд┐ рд╕реАрд╡рд░ рдХрд╛ 2/3 рднрд╛рдЧ рд╕реЗ рдЕрдзрд┐рдХ рднрд░рд╛ рд╣реБрдЖ рдирд╣реАрдВ рдкреНрд░рд╡рд╛рд╣рд┐рдд рд╣реЛрдиреА рдЪрд╛рд╣рд┐рдПред
рдЕрддрдГ рд╕реАрд╡рд░ рдХреА рдХреБрд▓ рдХреНрд╖рдорддрд╛
                =0.00938├Ч1.5
                 =0.01407 рдШрди рдореАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб
                   =0.01407 ├Ч 60
                  =0.845 рдШрди рдореАрдЯрд░ рдкреНрд░рддрд┐ рдорд┐рдирдЯ
 рдЕрддрдГ table 13.4( I.S.1742) рдХреЗ рдЕрдиреБрд╕рд╛рд░ 230 рдорд┐рдореА рд╡реНрдпрд╛рд╕ рдХреА рд╕реАрд╡рд░ рдкрд╛рдИрдк (Sewer Pipe) рдЙрдкрдпреБрдХреНрдд рд░рд╣реЗрдЧрд╛, рдЬрд┐рд╕рдореЗрдВ 0.75 рдореАрдЯрд░ рдкреНрд░рддрд┐ рд╕реЗрдХрдВрдб рдХреЗ рд╡реЗрдЧ рдкрд░ Sewage рдкреНрд░рд╡рд╛рд╣рд┐рдд рд╣реЛ рд╕рдХреЗрдЧрд╛ред
рд╕реАрд╡рд░ рдХрд╛ рдврд╛рд▓ 1in 175 рджрд┐рдпрд╛ рдЬрд╛рдПрдЧрд╛ред


What is Sewerage System? рд╕реАрд╡рд░реЗрдЬ рдкреНрд░рдгрд╛рд▓реА рдХреНрдпрд╛ рд╣реИ?

рдЗрд╕ рдкрджреНрдзрддрд┐ рдореЗрдВ рд╕реАрд╡реЗрдЬ рдХреЛ рдШрд░реЛрдВ рд╕реЗ рднреВрдорд┐рдЧрдд рдирд╛рд▓рд┐рдпреЛрдВ (Under Ground Drains) рджреНрд╡рд╛рд░рд╛ рд╢рд╣рд░реЛрдВ рдХреЗ рдмрд╛рд╣рд░ рдирд┐рд╖реНрдХрд╛рд╕рд┐рдд рдХрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред
рд╢рд╣рд░реЛрдВ рдХреЗ рдШрд░реЛрдВ рдХреЗ рдЕрдиреНрджрд░ Flush Laterine рдмрдирд╛рдИ рдЬрд╛рддреА рд╣реИред
Flush Laterine рдореЗ Night Soil рдХреЛ рд╕рдмрд╕реЗ рдЬреНрдпрд╛рджрд╛ рдкрд╛рдиреА рдХреА рдорд╛рддреНрд░рд╛ рдбрд╛рд▓ рдХрд░ рд╕реАрд╡рд░  (Sewers) рдореЗрдВ рдмрд╣рд╛ рджрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред
рдШрд░реЛрдВ рдХреЗ рдЕрдВрджрд░ Flush Laterine рдмрдирд╛рдИ рдЬрд╛рддреА рд╣реИред рдЬрд┐рд╕рдореЗрдВ Night Soil рдХреЛ рдмрд╣рд╛рдиреЗ рдХреЗ рд▓рд┐рдП рдкрд╛рдиреА рдХреА рдЯрдВрдХреА (Flushing Cistern) рд▓рдЧреА рд╣реЛрддреА рд╣реИред
рдЙрдкрдпреЛрдЧ рдХрд░рдиреЗ рдХреЗ рдмрд╛рдж  рдЪреИрди рдЦреАрдВрдЪрдиреЗ рдкрд░ Flushing Cistern рд╕реЗ 10 рд╕реЗ 15 рд▓реАрдЯрд░ рдкрд╛рдиреА рддреЗрдЬреА рд╕реЗ рдорд▓ рдкрд╛рддреНрд░ рдореЗрдВ рдШреБрд╕рддрд╛ рд╣реИред рдФрд░ рдорд▓ рдЖрджрд┐ рдХреЛ рдмрд╣рд╛рдХрд░ рд╕реАрд╡рд░ рдореЗрдВ рд▓реЗ рдЬрд╛рддрд╛ рд╣реИред
рд╕реАрд╡рд░ рдореЗрдВ рдмрд╣рддрд╛ рдпрд╣ рджреНрд░рд╡ рд╢рд╣рд░ рд╕реЗ рдмрд╛рд╣рд░ рдирд┐рдХрд▓ рдЬрд╛рддрд╛ рд╣реИред
рд╕реАрд╡реЗрдЬ рдореЗрдВ рдкрд╛рдиреА рдХреА рдорд╛рддреНрд░рд╛ 99.9% рдФрд░ рдареЛрд╕ рдкрджрд╛рд░реНрде рдХреЗрд╡рд▓ 0.1% рд╣реЛрддрд╛ рд╣реИред
Flush Laterine Sewage рдкреНрд░рд╡рд╛рд╣ рд╣реЛрддрд╛ рд╣реБрдЖ рдШрд░реЛрдВ рд╕реЗ рдмрд╛рд╣рд░ рдЖрдХрд░ рдирдЧрд░рдкрд╛рд▓рд┐рдХрд╛ рдХреА Sewer Line рдореЗрдВ рдЖрдХрд░ рдЧрд┐рд░рддрд╛ рд╣реИред
рд╕реАрд╡рд░ рд▓рд╛рдЗрди рджреНрд╡рд╛рд░рд╛ рдмрд╣рддрд╛ рд╣реБрдЖ рдШрд░реЛрдВ рд╕реЗ рдмрд╛рд╣рд░ рдЖрдХрд░ рд╢рд╣рд░ рд╕реЗ рдмрд╛рд╣рд░ рдирд┐рдХрд▓ рдЬрд╛рддрд╛ рд╣реИред
Sewer Line рдореЗрдВ рднреВрдорд┐ рдЧрдд рдХреБрдЫ рдЙрдЪрд┐рдд рд╡реНрдпрд╛рд╕ рдХреЗ рдкрд╛рдЗрдк рдмрд┐рдЫрд╛рдП рдЬрд╛рддреЗ рд╣реИрдВред 
рдЪрд┐рддреНрд░-Sewer Line 
Sewer Line рдХреЛ Hydraulic Theory рдХреЗ рдЕрдиреБрд╕рд╛рд░ рдЖрд╡рд╢реНрдпрдХ Longitudinal Slope рджрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред рдпрд╣ рдкрд╛рдИрдк  Sewer рдХрд╣рд▓рд╛рддреЗ рд╣реИрдВред
рдФрд░ рдЗрд╕ рдкреВрд░реЗ рд╡реНрдпрд╡рд╕реНрдерд╛ рдХреЛ Sewerage SystemтАМ рдХрд╣рддреЗ рд╣реИрдВред
рдирд┐рд░реАрдХреНрд╖рдг рдФрд░ рдЕрдиреБрд░рдХреНрд╖рдг рдХреЗ рд▓рд┐рдП Sewer Line рдкрд░ рдЙрдЪрд┐рдд рджреВрд░реА рдкрд░ Manhole рдмрдирд╛рдИ рдЬрд╛рддреА рд╣реИред рдЬрд┐рдирдХреЗ рдКрдкрд░ рдврд▓рд╡рд╛рдВ рд▓реЛрд╣рд╛ рдпрд╛ рдХрдВрдХреНрд░реАрдЯ рдХрд╛ рднрд╛рд░реА рдврд╝рдХреНрдХрди рд░рдЦрд╛ рдЬрд╛рддрд╛ рд╣реИред
рдЬрдм рдХрднреА Sewer рдХреА рд╕рдлрд╛рдИ рдХреА рдЖрд╡рд╢реНрдпрдХрддрд╛ рдкрдбрд╝рддреА рд╣реИред рдпрд╣ рдврд╝рдХреНрдХрди рдЙрдард╛рдХрд░ Man Hole рд╕реЗ рдиреАрдЪреЗ Sewer рдХреЗ рддрд▓реА рддрдХ рд╕рдлрд╛рдИ рдХрд░реНрдордЪрд╛рд░реА рдЖрд╕рд╛рдиреА рд╕реЗ рдкрд╣реБрдВрдЪ рд╕рдХрддреЗ рд╣реИрдВред
рд╕рдбрд╝рдХреЛрдВ рдФрд░ рдЕрдиреНрдп рд╕реНрдерд╛рдиреЛрдВ рд╕реЗ Storm Water рдПрд╡рдо рдЕрдиреНрдп рдЬрд▓ рдХреЛ Sewer Line рдореЗрдВ рдбрд╛рд▓рдиреЗ рдХреЗ рд▓рд┐рдП рд╕рдбрд╝рдХ рдХреЗ рдХрд┐рдирд╛рд░реЗ рдкрд░ Footpath рд╕реЗ рд▓рдЧрд╛ рдЙрдЪрд┐рдд рджреВрд░реА рдкрд░ рд╕рдбрд╝рдХ рдЫрд┐рджреНрд░ (Street Inlets) рдмрдирд╛рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред
Sewer рдореЗрдВ Sewage рдХреЗ рдЧрд▓рдиреЗ рд╕рдбрд╝рдиреЗ рддрдерд╛ рд╡рд┐рдпреЛрдЬрд┐рдд рд╣реЛрдХрд░ рдХрдИ рддрд░рд╣ рдХреЗ рдкреНрд░рджреВрд╖рд┐рдд рдЧреИрд╕реЛрдВ рдЬреИрд╕реЗ рд╣рд╛рдИрдбреНрд░реЛрдЬрди рд╕рд▓реНрдлрд╛рдЗрдб, рдХрд╛рд░реНрдмрди рдбрд╛рдЗрдСрдХреНрд╕рд╛рдЗрдб, рдореАрдереЗрди, рдЗрддреНрдпрд╛рджрд┐ рдЙрддреНрдкрдиреНрди рд╣реЛрддреА рд╣реИред
рдпрд╣ рд╕рднреА рд╡рд┐рд╖реИрд▓реЗ рдФрд░ рд╣рд╛рдирд┐рдХрд╛рд░рдХ рдЧреИрд╕реЗ рд╣реЛрддреА рд╣реИред
рдЗрди рдЧреИрд╕реЛрдВ рдХреЛ рд╕реАрд╡рд░ рд╕реЗ рдмрд╛рд╣рд░ рдирд┐рдХрд╛рд▓рдиреЗ рдХреЗ рд▓рд┐рдП Sewer Line рдкрд░ рдЙрдЪрд┐рдд рджреВрд░реА рдкрд░ Ventilation Shaft рд▓рдЧрд╛рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред Ventilation Shaft  рд╕реЗ рдирд┐рдХрд▓рдХрд░ рдпрд╣ рд╡рд┐рд╖реИрд▓реЗ рдЧреИрд╕реЗ рд╡рд╛рддрд╛рд╡рд░рдг рдореЗрдВ рдЪрд▓реА рдЬрд╛рддреА рд╣реИред
Sewage рдХреЛ рд╢рд╣рд░ рд╕реЗ рдмрд╛рд╣рд░ рд▓рд╛рдХрд░ рдЗрд╕рдХреЗ рдЙрдкрдЪрд╛рд░ (Treatment) рддрдерд╛ Disposal рдХреА рд╡реНрдпрд╡рд╕реНрдерд╛ рдХрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред
рдЬрд╣рд╛рдВ рдкрд░ рдпрд╣ рдХрд╛рд░реНрдп рд╕рдореНрдкрдиреНрди рд╣реЛрддрд╛ рд╣реИред рдЙрд╕реЗ Treatment works рдХрд╣рддреЗ рд╣реИрдВред

Sweage Disposal method
рд╕реАрд╡реЗрдЬ рд╕рдорд╛рдкрди рдХреА рджреЛ рд╡рд┐рдзрд┐рдпрд╛рдВ рд╣реИрдВред
рез.) рдкреНрд░рд╛рдХреГрддрд┐рдХ рд╕рдорд╛рдкрди рд╡рд┐рдзрд┐ 
Natural Disposal method
рдкреНрд░рд╛рдХреГрддрд┐рдХ рд╕рдорд╛рдкрди рд╡рд┐рдзрд┐ рдореЗрдВ Sewage рдХреЛ рд╢рд╣рд░ рдХреЗ рд╕рдореАрдкрд╡рд░реНрддреА рдХреНрд╖реЗрддреНрд░ рдореЗрдВ рдмрд╣рддреЗ рд╣реБрдП рдХрд┐рд╕реА рдирджреА- рдирд╛рд▓реЗ рдореЗрдВ рдкреНрд░рд╡рд╛рд╣рд┐рдд рдХрд░ рджрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред рдХрд┐рдиреНрддреБ рдЗрд╕рдХреЗ рд▓рд┐рдП рдирджреА рдореЗрдВ рд╣рд░ рдореМрд╕рдо рдореЗрдВ рдкрд░реНрдпрд╛рдкреНрдд рдорд╛рддреНрд░рд╛ рдореЗрдВ рдкрд╛рдиреА рдЙрдкрд▓рдмреНрдз рд╣реЛрдиреЗ рдЪрд╛рд╣рд┐рдПредрдЬрд┐рд╕рд╕реЗ рд╕реАрд╡реЗрдЬ рдХрд╛ Dilution рдЖрд╕рд╛рдиреА рд╕реЗ рд╣реЛ рд╕рдХреЗредрдХреБрдЫ рджреВрд░ рдмрд╣рдиреЗ рдкрд░ рдирджреА рдХрд╛ рдЬрд▓ Self purification process рд╕реЗ рдкреБрдирдГ рд╕реНрд╡рдЪреНрдЫ рд╣реЛ рдЬрд╛рддрд╛ рд╣реИред
реи.) рдХреГрддреНрд░рд┐рдо рд╕рдорд╛рдкрди рд╡рд┐рдзрд┐
Artificial Disposal Method
рдЗрд╕ рд╡рд┐рдзрд┐ рдореЗрдВ рд╢рд╣рд░ рдХреЗ рдмрд╛рд╣рд░ рдЙрдкрдЬрд╛рдК рднреВрдорд┐ рдЙрдкрд▓рдмреНрдз рд╣реЛрдиреЗ рдкрд░ рд╕реАрд╡реЗрдЬ рдЬрд▓ рджреНрд╡рд╛рд░рд╛ рдХреГрд╖рд┐ рдХрд╛рд░реНрдп рдХреЗ рд▓рд┐рдП рдкреНрд░рдпреЛрдЧ рдХрд┐рдпрд╛ рдЬрд╛ рд╕рдХрддрд╛ рд╣реИред рдХреНрдпреЛрдВрдХрд┐ рд╕реАрд╡реЗрдЬ рдореЗрдВ рдЦрд╛рдж (Manures) рдХреЗ рдЧреБрдг рд╡рд┐рджреНрдпрдорд╛рди рд╣реЛрддреЗ рд╣реИрдВред
рдЗрд╕ рдкреНрд░рдХрд╛рд░ рд╕реАрд╡реЗрдЬ рдХреЗ рдЙрдкрдпреЛрдЧ рдХреЛ рд╕реАрд╡реЗрдЬ рдЦреЗрддреА (Sewage Farming) рдХрд╣рддреЗ рд╣реИрдВред


  реНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреНреН

What is Bally Benching Process?

The Bally Benching Process is a slope stabilization technique used for slope protection, especially in hilly terrains and construction sites...